How-to guide

Underfloor Heating Thermostat Wiring: Electric and Water Systems

By Ismail Farooq · Updated 2026-10-30

Underfloor (radiant floor) heating comes in two very different kinds, and the thermostat for one won’t work for the other. Electric systems are heating mats or cables under the floor, controlled by a mains thermostat that switches the heating current itself. Water (wet, hydronic) systems are pipes fed from a boiler or heat pump through a manifold, and their thermostats only send a signal. Work out which you have before buying anything.

Electric floor heating thermostats switch the full heating load at 230 V (UK and Europe) or 120/240 V (North America). Turn off the circuit at the breaker, confirm with a voltage tester, and leave new circuits to an electrician.

Which system do you have?

ClueElectricWater (hydronic)
Where the heat comes fromMats or cables under tiles or flooringPipes fed from a boiler or heat pump
What’s in a cupboard or under a floorNothing; maybe a spur or breaker labelled “UFH”A manifold with flow meters and small actuators on top, and usually a pump and wiring centre
Wires at the thermostatHeavy mains wires plus a thin two-wire floor probeThin wires or a mains switched live to a wiring centre; or nothing if wireless
Typical roomsBathrooms, kitchens, one or two roomsWhole floors, new builds and extensions

Electric floor heating thermostats

These thermostats have three groups of terminals:

The two things that catch people out when replacing one:

  1. Match the floor probe. Probes are NTC sensors with different values (10k, 12k and 15k are common). A thermostat expecting a different value reads the floor temperature wrong and can overheat it. Many thermostats let you choose the probe type in settings; otherwise replace the probe or buy a thermostat that supports it. You can measure the probe with a multimeter on resistance: a 10k probe reads about 10 kΩ at 25 °C.
  2. Check the load. Add up the mats’ wattage and divide by the voltage. Thermostats in the UK and Europe are commonly rated 16 A, about 3,680 W at 230 V. Larger areas need a contactor or a second thermostat.

Electric floor heating needs RCD protection (30 mA) in the UK and Europe. In North America, floor heating in bathrooms and kitchens must be GFCI protected, and many floor thermostats have a GFCI built in with a test button. A new circuit for floor heating in a bathroom is notifiable work under Part P in England and Wales, so use a registered electrician.

Water underfloor heating

Each room or zone has a thermostat and one or more actuators, small heads on the manifold that open that room’s loop. A wiring centre next to the manifold links them all:

Wiring centres come in 230 V and 24 V versions, and the thermostats and actuators must match the wiring centre’s voltage. A 230 V wiring centre normally takes a switched live from each room thermostat; a 24 V one supplies its own low voltage. Wireless thermostats pair with a receiver in the wiring centre instead.

Making water UFH smart

Settings for underfloor heating

When it isn’t heating

Popular wiring setups

Related guides