Wiring guide

3-Wire Thermostat (Heat + Fan, No C Wire)

Three wires on R, W and G control a furnace’s heat and blower but not AC, and there is no C wire. Some smart thermostats cope; others need extra wire.

Detected system: 1-stage heat, fan, no C wire · 3 wires

Smart thermostat compatibility

ThermostatVerdictWhat to know
Nest Learning (4th gen)Works with an adapterGoogle says heat-only, cool-only and heat pump systems without a C wire need a C wire or the Nest Power Connector.
ecobee PremiumWorks with an adapterNo C wire and too few wires for a furnace adapter. Best fix: run a new 18/5 thermostat cable. Alternative: a plug-in 24 VAC adapter wired to Rc and C, with your existing heat circuit moved to Rh (the ecobee Premium supports split power).
ecobee EnhancedWorks with an adapterNo C wire and too few wires for a furnace adapter. Best fix: run a new 18/5 thermostat cable. Alternative: a plug-in 24 VAC adapter wired to Rc and C, with your existing heat circuit moved to Rh (the ecobee Enhanced supports split power).
Honeywell T9Works with an adapterNo C wire and too few wires for a furnace adapter. Best fix: run a new 18/5 thermostat cable. Alternative: a plug-in 24 VAC adapter wired to Rc and C, with your existing heat circuit moved to Rh (the Honeywell T9 supports split power).
Amazon Smart ThermostatNot compatibleNo C wire and too few wires for an adapter. You’ll need a new 18/5 thermostat cable from the equipment to the wall.

Where each wire goes, thermostat by thermostat

Old wireNest Learning (4th gen)ecobee Premiumecobee EnhancedHoneywell T9Amazon Smart Thermostat
R (red)Rc or RhRhRhRhR
W (white)WW1W1WW
G (green)GGGGG

Colors are typical, not a rule: always go by the letter the wire was connected to. Click a thermostat for its full diagram, parts and app settings.

How to confirm this is your setup

Three wires on R, W and G, with no Y. Your furnace has a blower you can switch on by itself, but the thermostat was never wired for air conditioning. If you do have central AC, the cooling wire may be connected somewhere else, so check the furnace control board before you assume.

Mistakes to avoid

Our advice

Look behind the wall plate and at the furnace for extra conductors that are folded back and unused. A spare wire in the same cable can become your C wire with no new cable. Connect it to C at both ends.

Link to this diagram

Copy this code to share this wiring diagram on your site or forum post.

Other wiring setups